dfam-check
GitHub用于评估3D网格文件是否符合增材制造(DfAM)规则,支持多种工艺,提供可打印性分析、支撑建议及优化指导。
Trigger Scenarios
Install
npx skills add earthtojake/text-to-cad --skill dfam-check -g -y
SKILL.md
Frontmatter
{
"name": "dfam-check",
"description": "Measure mesh files against Design for Additive Manufacturing (DfAM) rules and report printability findings per process (FDM, SLS, SLA\/DLP, metal PBF, MJF). Use when the user asks whether a part is printable, wants overhang\/wall-thickness\/support analysis of an `.stl`, `.obj`, `.ply`, or `.3mf` mesh, wants a build-orientation recommendation, or wants DfAM redesign guidance before slicing with `$gcode` or regenerating geometry with `$cad`."
}
DfAM Check
Provenance: maintained in earthtojake/text-to-cad. Use the installed local skill files as the runtime source of truth; the repository link is only for provenance and release review.
Use this skill to produce conservative, evidence-backed DfAM reports for mesh files before slicing or printing. It measures geometry facts locally and compares them against per-process design limits; it never slices, uploads, or starts print jobs.
Geometry Inspection
Use scripts/dfam_tool.py in the active project Python environment for all
geometry facts (requires trimesh, numpy, rtree). The tool is fact-only:
it reports measurements and never emits pass/fail or readiness statuses.
Comparisons and verdicts belong to this workflow. Do not estimate wall
thickness, overhang angles, or support volume by eye or from renders when the
tool can measure them.
python scripts/dfam_tool.py measure part.stl --angle-limit 45
python scripts/dfam_tool.py orientations part.stl --angle-limit 45
Set --angle-limit to the target process's self-supporting angle from
references/process-limits.md before measuring, and re-run when the target
process changes: the aggregate support-area facts are binned against it.
STEP/STP input is boundary-representation CAD, not a mesh. When the $cad
skill is installed, export an STL sidecar with it first, then measure the STL
here. Report that remediation instead of attempting raw STEP parsing.
Workflow
- Collect print intent: target process, material, layer height, and any machine or material datasheet the user can provide. If the process is unknown, measure once with the default 45° limit, then present findings per candidate process rather than guessing a single verdict.
- Read
references/process-limits.mdand select the limit column for the target process. A user-provided machine/material datasheet overrides the defaults; cite whichever source is used for every comparison. - Run
measureon the exact upload file. Do not inspect only a generator script, source CAD model, or console summary of the file. - Run
orientationswhen the process requires supports and the measured support area is nonzero. Report any candidate that materially reduces support area, with its build-height tradeoff. - Compare each measured fact to the cited limit and report findings with
restrained status labels:
✅ pass: the measured fact satisfies the cited limit.❌ fail: a measured fact directly violates the cited limit.❓ need more info: missing process context, unmeasured geometry, sampling too sparse to trust, or tool limitations.
- Order findings by severity: watertightness first (blocks slicing for every process), then wall thickness, then overhangs/supports, then orientation and cost signals.
Comparison
Compare only trustworthy pairs of evidence.
- Cite the limit source (process-limits table row, or the user's datasheet field) and the measured fact (JSON field path) for every finding.
- Treat
p05_mmbelow the wall-thickness limit as a violation even whenmin_mmalone could be a sampling outlier; report both values. - On an assembly,
wall_thicknessreportsbody_countand aper_bodybreakdown. Attribute a violation to the body it belongs to; a thin figure pooled across bodies is not a finding against the part as a whole. - Do not apply support-angle findings to powder processes (SLS, MJF); the
relevant powder-process check is trapped-volume powder escape, which this
tool does not yet measure — report that as
❓ need more infowhen enclosed cavities are likely. - Do not silently rescale geometry.
scale.units_suspectis measured from the bounding-box diagonal: when it istrue, the source is probably in meters or inches, every down-facing face reads as resting on the plate, and overhang and support figures of 0.0 mean nothing. Report a unit/scale finding and ask the user to confirm units before comparing anything against a material limit. - Support-volume ratios are coarse upper bounds; report them as cost signals, not hard failures, unless the user has set an explicit budget.
Redesign Handoff
For every ❌ fail, include a concrete, plain-language redesign instruction
with target numbers (for example "thicken the wall at [12.4, 3.0, 8.1] from
0.6 mm to ≥1.2 mm" or "chamfer the overhang at [23.3, 10.0, 52.0] to ≥45°").
When the $cad skill is installed, offer to apply the redesign instructions
with it and re-measure the regenerated geometry here, repeating until no
❌ fail findings remain. When $cad-viewer is installed, hand the measured
file path(s) to it so the user can inspect the findings visually.
Version History
- 0.4.28 Current 2026-08-27 16:54


